Product Categories
1. Tinned Copper Conductor(Class 5)
2. XLPO Insulation
3. XLPO Sheath
1.Voltage Rating: DC1500V
2. Operating Temp.: Under 120°C
3. Minimum Bending Radius: ≥ 6D, D is the outer diameter of the cable
4. Ambient Temperature at Laying: ≥ -20℃
5. Electrical Properties: Withstand frequency AC voltage 6.5kV / 5 minutes without breakdown
6. Low smoke, halogen-free, flame retardant, UV resistant, weather resistant
DC1500V CU/XLPO/XLPO PV
1.Sheath: XLPO
2.Insulation: XLPO
3.Conductor: Class 5 Tinned Copper Conductor
TUV 2pfg 1169/08.2007
IEC 60228
EN 56078
IEC 62930
TUV 2pfg 1990/05.2012
UL 4703 PV Wire
Solar Energy
Specification | Wire Diameter | DC | Insulation | Sheath Thickness | Insulation | Approx. Overall |
1×2.5 | 0.26 | 8.21 | 0.50 | 0.50 | 1000 | 4.4 |
1×4 | 0.31 | 5.09 | 0.50 | 0.50 | 1000 | 4.9 |
1×6 | 0.31 | 3.39 | 0.50 | 0.50 | 1000 | 5.5 |
1×10 | 0.41 | 1.95 | 0.50 | 0.50 | 1000 | 7.1 |
1×16 | 0.41 | 1.24 | 0.50 | 0.50 | 1000 | 8.5 |
1×25 | 0.41 | 0.795 | 0.50 | 0.50 | 1000 | 10.3 |
1×35 | 0.41 | 0.565 | 0.50 | 0.50 | 1000 | 12.3 |